Limiting factors of peak and submaximal exercise capacity in LVAD patients

Posted on 2020-07-09 - 22:06

Aims

Although patients supported with a Continuous-Flow Left Ventricular Assist Device (CF-LVAD) are hemodynamically stable, their exercise capacity is limited. Hence, the aim of this work was to investigate the underlying factors that lead to peak and submaximal exercise intolerance of CF-LVAD supported patients.

Methods

Seven months after CF-LVAD implantation, eighty three patients performed a maximal cardiopulmonary exercise test and a six minute walk test. Peak oxygen uptake and the distance walked were measured and expressed as a percentage of the predicted value (%VO2p and %6MWD, respectively). Preoperative conditions, echocardiography, laboratory results and pharmacological therapy data were collected and a correlation analysis against %VO2p and %6MWD was performed.

Results

CF-LVAD patients showed a relatively higher submaximal exercise capacity (%6MWD = 64±16%) compared to their peak exertion (%VO2p = 51±14%). The variables that correlated with %VO2p were CF-LVAD parameters, chronotropic response, opening of the aortic valve at rest, tricuspid insufficiency, NT-proBNP and the presence of a cardiac implantable electronic device. On the other hand, the variables that correlated with %6MWD were diabetes, creatinine, urea, ventilation efficiency and CF-LVAD pulsatility index. Additionally, both %6MWD and %VO2p were influenced by the CF-LVAD implantation timing, calculated from the occurrence of the cardiac disease.

Conclusion

Overall, both %6MWD and %VO2p depend on the duration of heart failure prior to CF-LVAD implantation. %6MWD is primarily determined by parameters underlying the patient’s general condition, while %VO2p mostly relies on the residual function and chronotropic response of the heart. Moreover, since %VO2p was relatively lower compared to %6MWD, we might infer that CF-LVAD can support submaximal exercise but is not sufficient during peak exertion. Hence concluding that the contribution of the ventricle is crucial in sustaining hemodynamics at peak exercise.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email
need help?